Passivity-Based Control Strategy for SMES Under an Unbalanced Voltage Condition
Authors
Yong Lei, Xiaodong Lin, Yingwei Zhu
Abstract
This paper presents a novel nonlinear control strategy for a superconducting magnetic energy storage (SMES) system during network unbalance. Grid voltage unbalances tend to substantially degrade the operation of a SMES system; conventional control methods cannot completely address this issue. In this paper, three selectable control targets for the SMES are identified according to the working principle of the SMES under an unbalanced voltage condition to reduce the impacts of second harmonics in output power, output reactive power, and grid-side current. Next, the port-controlled Hamiltonian models of the SMES are established, and the positive- and negative-sequence interconnection and damping assignment passivity-based control (PBC) strategies are proposed accordingly. Simulation results show that the PBC has stronger robustness in both steady and dynamic states compared with the conventional proportional integral method, which effectively suppresses the oscillations caused by the unbalanced voltage.
Citation
- Journal: IEEE Access
- Year: 2018
- Volume: 6
- Issue:
- Pages: 28768–28776
- Publisher: Institute of Electrical and Electronics Engineers (IEEE)
- DOI: 10.1109/access.2018.2831251
BibTeX
@article{Lei_2018,
title={{Passivity-Based Control Strategy for SMES Under an Unbalanced Voltage Condition}},
volume={6},
ISSN={2169-3536},
DOI={10.1109/access.2018.2831251},
journal={IEEE Access},
publisher={Institute of Electrical and Electronics Engineers (IEEE)},
author={Lei, Yong and Lin, Xiaodong and Zhu, Yingwei},
year={2018},
pages={28768--28776}
}
References
- hamed, A novel dynamic switching table based direct power control strategy for grid connected converters. IEEE Trans Energy Convers (0)
- Saber, B., Abdelkader, B., Said, B. & Mansour, B. Integral sliding mode control of four-leg DSTATCOM coupled with SMES unit. 2017 5th International Conference on Electrical Engineering - Boumerdes (ICEE-B) 1–6 (2017) doi:10.1109/icee-b.2017.8192037 – 10.1109/icee-b.2017.8192037
- Tang, Y. F., He, H. B. & Mu, C. X. Superconducting magnetic energy storage based power system control using ADP. 2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD) 87–88 (2015) doi:10.1109/asemd.2015.7453479 – 10.1109/asemd.2015.7453479
- Xing, Y. Q., Jin, J. X., Wang, Y. L., Du, B. X. & Wang, S. C. An Electric Vehicle Charging System Using an SMES Implanted Smart Grid. IEEE Trans. Appl. Supercond. 26, 1–4 (2016) – 10.1109/tasc.2016.2602245
- Zoghlami, M. & Bacha, F. Implementation of different strategies of Direct Power Control. IREC2015 The Sixth International Renewable Energy Congress 1–6 (2015) doi:10.1109/irec.2015.7110954 – 10.1109/irec.2015.7110954
- Siew-Chong Tan, Lai, Y. M. & Tse, C. K. General Design Issues of Sliding-Mode Controllers in DC–DC Converters. IEEE Trans. Ind. Electron. 55, 1160–1174 (2008) – 10.1109/tie.2007.909058
- Cheng, P. & Nian, H. Collaborative Control of DFIG System During Network Unbalance Using Reduced-Order Generalized Integrators. IEEE Trans. Energy Convers. 30, 453–464 (2015) – 10.1109/tec.2014.2363671
- Busada, C. A., Gomez Jorge, S., Leon, A. E. & Solsona, J. A. Current Controller Based on Reduced Order Generalized Integrators for Distributed Generation Systems. IEEE Trans. Ind. Electron. 59, 2898–2909 (2012) – 10.1109/tie.2011.2167892
- Xu, L., Andersen, B. R. & Cartwright, P. VSC Transmission Operating Under Unbalanced AC Conditions—Analysis and Control Design. IEEE Trans. Power Delivery 20, 427–434 (2005) – 10.1109/tpwrd.2004.835032
- Xu, L. & Wang, Y. Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions. IEEE Trans. Power Syst. 22, 314–323 (2007) – 10.1109/tpwrs.2006.889113
- Qu, Y. B. & Song, H. H. Energy-based coordinated control of wind energy conversion system with DFIG. International Journal of Control 84, 2035–2045 (2011) – 10.1080/00207179.2011.631588
- Chen, L. et al. Conceptual Design and Evaluation of an HTS Magnet for an SMES Used in Improving Transient Performance of a Grid-Connected PV System. IEEE Trans. Appl. Supercond. 28, 1–8 (2018) – 10.1109/tasc.2017.2783349
- Svensson, J., Bongiorno, M. & Sannino, A. Practical Implementation of Delayed Signal Cancellation Method for Phase-Sequence Separation. IEEE Trans. Power Delivery 22, 18–26 (2007) – 10.1109/tpwrd.2006.881469
- Chen, L. et al. SMES-Battery Energy Storage System for the Stabilization of a Photovoltaic-Based Microgrid. IEEE Trans. Appl. Supercond. 28, 1–7 (2018) – 10.1109/tasc.2018.2799544
- Deng, J., Shi, J., Liu, Y. & Tang, Y. Application of a hybrid energy storage system in the fast charging station of electric vehicles. IET Generation Trans & Dist 10, 1092–1097 (2016) – 10.1049/iet-gtd.2015.0110
- Guo, W. et al. Development of a 1-MVA/1-MJ Superconducting Fault Current Limiter–Magnetic Energy Storage System for LVRT Capability Enhancement and Wind Power Smoothing. IEEE Trans. Appl. Supercond. 28, 1–5 (2018) – 10.1109/tasc.2018.2800000
- Chen, Z., Xiao, X. Y., Li, C. S., Zhang, Y. & Zheng, Z. X. Study on Unit Commitment Problem Considering Large-Scale Superconducting Magnetic Energy Storage Systems. IEEE Trans. Appl. Supercond. 26, 1–6 (2016) – 10.1109/tasc.2016.2598353
- Zheng, Z. X., Xiao, X. Y., Li, C. S., Chen, Z. & Zhang, Y. Performance Evaluation of SMES System for Initial and Steady Voltage Sag Compensations. IEEE Trans. Appl. Supercond. 26, 1–5 (2016) – 10.1109/tasc.2016.2582844
- Chang, L. Review on Distributed Energy Storage Systems for Utility Applications. CPSS TPEA 2, 267–276 (2017) – 10.24295/cpsstpea.2017.00025
- Ngamroo, I. Optimization of SMES-FCL for Augmenting FRT Performance and Smoothing Output Power of Grid-Connected DFIG Wind Turbine. IEEE Trans. Appl. Supercond. 26, 1–5 (2016) – 10.1109/tasc.2016.2592945
- Jabir, M., Azil Illias, H., Raza, S. & Mokhlis, H. Intermittent Smoothing Approaches for Wind Power Output: A Review. Energies 10, 1572 (2017) – 10.3390/en10101572
- Guoqiao Shen, Xuancai Zhu, Jun Zhang & Dehong Xu. A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter. IEEE Trans. Ind. Electron. 57, 2033–2041 (2010) – 10.1109/tie.2010.2040552
- Ortega, R. & García-Canseco, E. Interconnection and Damping Assignment Passivity-Based Control: A Survey. European Journal of Control 10, 432–450 (2004) – 10.3166/ejc.10.432-450
- Putting energy back in control. IEEE Control Syst. 21, 18–33 (2001) – 10.1109/37.915398
- Serra, F. M., De Angelo, C. H. & Forchetti, D. G. Interconnection and damping assignment control of a three-phase front end converter. International Journal of Electrical Power & Energy Systems 60, 317–324 (2014) – 10.1016/j.ijepes.2014.03.033
- Jeltsema, D., Ortega, R. & M.A. Scherpen, J. An energy-balancing perspective of interconnection and damping assignment control of nonlinear systems. Automatica 40, 1643–1646 (2004) – 10.1016/j.automatica.2004.04.007
- Wang, J. & Yin, H. Passivity Based Controller Design Based on EL and PCHD Model. Procedia Engineering 15, 33–37 (2011) – 10.1016/j.proeng.2011.08.008
- Song, H. H. & Qu, Y. B. Energy-based modelling and control of wind energy conversion system with DFIG. International Journal of Control 84, 281–292 (2011) – 10.1080/00207179.2010.550064